Chalmette Refining, LLC, Chalmette

LDEQ Incident Report

Incident #No LDEQ Number Available
State Police #05-09007
Incident Date2005-12-18
Report Date 2005-12-21
Follow-up Date 0000-00-00
Follow-up: No

Pollutants Released

Pollutant Duration Point Source Greenhouse Gas Criteria Pollutant Ozone forming chemical Amount of Release
Nitric Oxide10h 5mCoker 2 Wet Gas Compressor K8101NOYESNO254.0 pounds
Nitrogen Dioxide10h 5mCoker 2 Wet Gas Compressor K8101NOYESYES28.0 pounds
Sulfur Dioxide10h 5mCoker 2 Wet Gas Compressor K8101NOYESNO26,127.0 pounds

Cause of Problem: Equipment Failure

Compressor went into high alarm for high vibration. It was determined that the vibration probe had provided a false alarm due to a faulty connection.

Discharge Preventable - No

Notes/Remedial Actions

In order to avoid equipment damage and associated emissions, refinery personnel shut down the machine. The vibration probe was repaired and the machine was put back in service, ending the incident. Instrument and electrical connections directly relatedto K8101 were double checked for proper connections in order to avoid a recurrence due to the same root cause.